These fire sprinkler systems have a fast opening tool to get rid of the air and speed up the flow of water.
Dry fire sprinkler system.
These include wet dry deluge pre action and foam.
This air holds a remote valve known as a dry pipe valve in a closed position.
This way if and when temperatures drop below freezing the pipes are not in danger of freezing.
The pressure from the air holds a valve closed that has water behind it.
A dry fire sprinkler system might not be what you think.
A dry pipe sprinkler system is one in which pipes are filled with pressurized air or nitrogen rather than water.
Evidenced in research and development in the area of dry pipe sprinkler systems it is clear victaulic is committed to increased safety convenience and design flexibility.
Rather a dry fire sprinkler keeps pressurized air and or nitrogen in the non heated portions of the sprinkler pipes.
A dry pipe sprinkler system is designed so that the piping itself is filled with pressurized air instead of water explains ken isman vice president of engineering for the national fire sprinkler association.
It does not use dry chemicals to suppress a fire.
Nowadays dry pipe fire sprinkler systems come in all shapes and sizes but the main function is still avoiding pipe freeze ups and system impairments while providing uncompromising fire protection.
Although historically only used in factories and large commercial buildings systems for homes and small buildings are now available at a cost effective price.
The pressurized air holds back the water supply at a main dry pipe valve.
Dry fire sprinkler systems on the other hand do not have water in the direct non heated sprinkler piping but only pressurized air or nitrogen.
This allows for a quick reaction to a fire and is the most common type.
Each has its own unique set of characteristics that protect the specific building and property for which it was installed.
A fire sprinkler system is an active fire protection method consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system onto which fire sprinklers are connected.
Wet pipe fire sprinklers constantly have water in them.
Located in a heated space the dry pipe valve prevents water from entering the pipe until a fire causes one or more sprinklers to operate.
Because fire sprinkler systems protect a variety of buildings and property many different types have been developed over the years.